GE Q-Line Ground Fault Circuit Breaker, Type THQL Model 3 Self-Test, 120 VAC, 15 A, 10 kA Interrupt, Q-Line Frame, Non-Interchangeable/LIG Trip, 5 mA Trip, 1 Pole, 1 ph, 14 to 8 AWG Cu, 12 to 8 AWG Al Wire, Plug-In Mounting, 3-9/32 in H x 1 in W x 2-3/8 in D Dimensions
UL 489 File No. E51075|cULus Listed|Federal Specification W-C-375B|HACR Rated
                
                
                    
                        The national electrical code requires GFCI protection of receptacles located outdoors, in bathrooms, garages and spa areas|This applies not only to new construction, but also to existing homes|When an electrical outlet is replaced in a location that requires ground fault protection, the new outlet must be GFCI protected, according to the NEC|The GFCI circuit interrupter provides protection against overloads, short circuits and ground faults|It detects very low levels of electrical current leakage (ground faults) and acts quickly to shut off power, preventing serious shock|Push button test validates the ground fault detection capability of the breaker|Class A 5 mA ground fault circuit interrupter|Quick-make, quick-break mechanism|Suitable for reverse feed|Standard continuous current rated|Feeder plug-in circuit breakers|60 deg C/75 deg F conductor rating|Box type terminals|Multi-pole circuit breakers incorporate internal common trip
                    
                
                
                    
                        
                            
                                
                                    Amperage Rating
                                    15
                                
                            
                                
                                    Dimensions
                                    3-9/32 in H x 1 in W x 2-3/8 in D
                                
                            
                                
                                    Frame
                                    Q-Line
                                
                            
                                
                                    Interrupt Rating
                                    10
                                
                            
                                
                                    Mounting Type
                                    Plug-In
                                
                            
                                
                                    Number of Poles
                                    1
                                
                            
                                
                                    Phase
                                    1
                                
                            
                                
                                    Trip Range
                                    5
                                
                            
                                
                                    Trip Type
                                    Non-Interchangeable/LIG
                                
                            
                                
                                    Type
                                    Type THQL Model 3 Self-Test
                                
                            
                                
                                    Voltage Rating
                                    120
                                
                            
                                
                                    Wire Size
                                    14 to 8 AWG Cu, 12 to 8 AWG Al
                                
                            
                                
                                    Brand
                                    GE
                                
                            
                                
                                    Manufacturer
                                    ABB